9.17.5. Ropes

Removal

PERFORMANCE ORDER
1. To remove the heating regulator.
2. To disconnect ropes from control levers and to take out, having removed before it the screw-driver lamellar clips of braids of ropes.

Installation

PERFORMANCE ORDER
1. To install ropes on the heating regulator.
2. To establish braids of ropes on a regulator emphasis, then by means of pincers to establish and latch lamellar clips.
3. To install the heating regulator.

Adjustment

PERFORMANCE ORDER
1. To install the wire lever so that ropes (1, 2, 3) were most extended: to shift the lever (5) (to the gate of legs of the driver) up to the end to the right, (4) (to the adjusting valve), to the left, (6) (to the defroster gate) to the left.
2. To push a rope to the adjusting valve through a cross wall in a motor compartment and to suspend.
3. To shift the lever (2) against the stop to the right (the valve is closed). To fix a rope braid on the adjusting valve by a lamellar clip (1).
4. To shift the defroster gate lever in the direction of an arrow against the stop and to fix a rope braid.
5. To shift the gate lever for the driver's legs in the direction of an arrow against the stop and to fix a rope braid.
6. Adjustment of gates: to move heating regulator control levers from an emphasis against the stop. Ropes will be adjusted.